{"product_id":"hager-circuit-breaker-1p-6a-curve-b-10ka-icn-15ka-icu-1-module-nbn106a","title":"Hager Circuit breaker 1P 6A Curve B 10kA Icn \/ 15kA Icu 1 Module NBN106A","description":"\u003ch2\u003eHager NBN106A 6A Type B Single-Pole Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe Hager NBN106A is a high-performance 6A Type B miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. Its compact one-module design combines a 10kA rated short-circuit breaking capacity with biconnect terminals for use in compatible residential and light-commercial distribution boards.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated current:\u003c\/strong\u003e 6A at 30°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTripping curve:\u003c\/strong\u003e Type B\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking capacities:\u003c\/strong\u003e 10kA Icn, 7.5kA Ics and 15kA Icu\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Single pole (1P), one module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating voltage:\u003c\/strong\u003e 230–400V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Screw terminal with biconnect bottom connection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEndurance:\u003c\/strong\u003e 20,000 mechanical and 4,000 electrical operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting flexibility:\u003c\/strong\u003e 360° mounting position possible\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection rating:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental compliance:\u003c\/strong\u003e RoHS conform\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellpadding=\"6\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color: #eeeeee;\"\u003e\u003cth colspan=\"2\"\u003eHager NBN106A Technical Data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eElectrical\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated current IN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated service breaking capacity Ics at 230V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.50 kA according to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated service breaking capacity Ics AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50% according to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated service breaking capacity Ics AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.50 kA according to IEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-circuit breaking capacity Icn at 230V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA according to IEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated short-circuit breaking capacity Icn AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kA according to IEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated ultimate short-circuit breaking capacity Icu AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA according to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated ultimate short-circuit breaking capacity Icu at 230V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 kA according to IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated operational voltage Ue\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230–400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage Ui\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated impulse withstand voltage Uimp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation at IN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.33 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy limitation class I²t\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eArchitecture \u0026amp; Installation\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTop connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBottom connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBiconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection alignment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAligned terminal, top and bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal tightening torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.80–2.80 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360° mounting possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRigid conductor cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlexible conductor cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical endurance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical endurance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eRated Current by Ambient Temperature\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-15°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.26 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-10°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-5°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e0°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.87 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.73 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e10°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.59 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e15°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.45 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e25°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e30°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e35°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.84 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e40°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.68 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e45°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.52 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e50°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e55°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e60°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.99 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e65°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e70°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eDimensions \u0026amp; General\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e83 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrid distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 according to IEC 60664 \/ IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25–70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRoHS conform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3250614618017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e1 × Hager NBN106A 6A Type B single-pole circuit breaker\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellpadding=\"6\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003cth\u003eDocument\u003c\/th\u003e\n\u003cth\u003eDownload\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Environmental Profile – MCB 1P 6kA B-16A, 1 module\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/assets.hager.com\/step-content\/P\/HA_84320273\/Document\/std.lang.all\/PEP_HAGE-00928-V03.01-EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView PDF\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREACH Declaration – NBN106A\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/assets.hager.com\/step-content\/P\/PRE_45269712EN\/Document\/std.lang.all\/reach_declaration_NBN106A_en-GB.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView PDF\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Report – NBN106A\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/assets.hager.com\/step-content\/P\/PRO_45269712EN\/Document\/std.lang.all\/rohs_declaration_NBN106A_en-GB.pdf\" target=\"_blank\" rel=\"noopener\"\u003eView PDF\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp\u003eNeed help checking compatibility with your distribution board or installation? Contact The Lighting Gallery team before ordering. Electrical installation should be carried out by a suitably qualified professional.\u003c\/p\u003e","brand":"thelightinggallery","offers":[{"title":"Default Title","offer_id":58864905879887,"sku":"NBN106A","price":2.49,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0880\/2264\/7119\/files\/NBN106A_44338dca-1c91-4282-a109-c95f9f2d12aa.jpg?v=1790162510","url":"https:\/\/www.thelightinggallery.co.uk\/products\/hager-circuit-breaker-1p-6a-curve-b-10ka-icn-15ka-icu-1-module-nbn106a","provider":"thelightinggallery","version":"1.0","type":"link"}