{"product_id":"hager-consumer-unit-surge-protection-kit-type-2-vme02spd","title":"Hager Consumer Unit Surge Protection Kit Type 2 VME02SPD","description":"\u003ch2\u003eHager VME02SPD Type 2 Surge Protection Kit\u003c\/h2\u003e\n\u003cp\u003eThe Hager VME02SPD is a Type 2 surge protection kit for consumer units and distribution boards. It provides voltage-limiting protection for TN and TT networks, with a 275 V continuous operating voltage, 1.35 kV voltage protection level and optical disconnector indication. Its built-in installation format is designed for indoor use.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType 2 surge protection:\u003c\/strong\u003e IEC 61643 requirement class T2 for protecting electrical installations against transient overvoltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage-limiting design:\u003c\/strong\u003e 275 V continuous operating voltage Uc and 1.35 kV protection level Up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDischarge performance:\u003c\/strong\u003e 40 kA maximum discharge current, 20 kA nominal discharge current and 25 kA short-circuit current rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork compatibility:\u003c\/strong\u003e Designed for TN and TT network configurations, with L-N and L-PEN protection modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Built-in installation for indoor use with optical disconnector indication.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection and durability:\u003c\/strong\u003e IP20 enclosure, operating temperature from -40 to 80°C and maximum altitude of 2,000 m.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color: #eeeeee;\"\u003e\u003cth colspan=\"2\"\u003eHager VME02SPD Technical Data\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eVoltage\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eReference test voltage Utest AC\u003c\/th\u003e\n\u003ctd\u003e255 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOvervoltage category according to IEC 60947-1\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType voltage supply\u003c\/th\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eContinuous operating voltage Uc according to IEC 61643-1\u003c\/th\u003e\n\u003ctd\u003e275 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVoltage protection level Up according to IEC 61643-1\u003c\/th\u003e\n\u003ctd\u003e1.35 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal voltage\u003c\/th\u003e\n\u003ctd\u003e240 V AC ± 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode of protection design\u003c\/th\u003e\n\u003ctd\u003eVoltage-limiting type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eEquipment and Use Conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWith remote signalling contact\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-40 - 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum altitude\u003c\/th\u003e\n\u003ctd\u003e2,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDegree of pollution according to IEC 60664 \/ IEC 60947-2\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStorage\/transport temperature\u003c\/th\u003e\n\u003ctd\u003e-40 - 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAir humidity protection\u003c\/th\u003e\n\u003ctd\u003e5 - 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eStandards and Frequency\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRequirement class IEC 61643\u003c\/th\u003e\n\u003ctd\u003eT2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eDimensions and Connectivity\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e95 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMounting type\u003c\/th\u003e\n\u003ctd\u003eBuilt in installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eElectrical and Discharge Performance\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eShort-circuit current rating (Isccr)\u003c\/th\u003e\n\u003ctd\u003e25 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum discharge current (Imax)\u003c\/th\u003e\n\u003ctd\u003e40 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum overcurrent protection device, parallel connection (fuse)\u003c\/th\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal discharge current In\u003c\/th\u003e\n\u003ctd\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eFunctions and Installation\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDisconnector indication\u003c\/th\u003e\n\u003ctd\u003eOptical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSuitable for indoor usage\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eSafety\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMode of protection\u003c\/th\u003e\n\u003ctd\u003eL-N, L-PEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTOV behaviour at UT\u003c\/th\u003e\n\u003ctd\u003e350 V AC (5 s \/ withstand mode), 460 V AC (120 min \/ safe failure mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress Protection (IP) class\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eMaterials and Network\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaterial\u003c\/th\u003e\n\u003ctd\u003ePolyamide (PA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eColour\u003c\/th\u003e\n\u003ctd\u003eLight grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRAL code\u003c\/th\u003e\n\u003ctd\u003e7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNetwork type\u003c\/th\u003e\n\u003ctd\u003eTN, TT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEAN shown in existing product description\u003c\/th\u003e\n\u003ctd\u003e5015652608714\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurrent product barcode\u003c\/th\u003e\n\u003ctd\u003e5015652606444\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRoHS conform\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cp\u003eHager VME02SPD Type 2 surge protection kit. Additional accessories are not specified in the available product information.\u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003cth\u003eDocument\u003c\/th\u003e\n\u003cth\u003eFormat\u003c\/th\u003e\n\u003cth\u003eLink\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEP - 12 Way 100A Metal Customer Unit Round KO + T2 SPD (English)\u003c\/td\u003e\n\u003ctd\u003ePDF\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/assets.hager.com\/step-content\/P\/HA_85049435\/Document\/std.lang.all\/PEP_HAGE-00962-V02.01-EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREACH declaration VME02SPD\u003c\/td\u003e\n\u003ctd\u003ePDF\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/assets.hager.com\/step-content\/P\/PRE_39760251EN\/Document\/std.lang.all\/reach_declaration_VME02SPD_en-GB.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHager RoHS report VME02SPD\u003c\/td\u003e\n\u003ctd\u003ePDF\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/assets.hager.com\/step-content\/P\/PRO_39760251EN\/Document\/std.lang.all\/rohs_declaration_VME02SPD_en-GB.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor help checking compatibility or selecting the right surge protection device, please contact thelightinggallery.\u003c\/p\u003e","brand":"thelightinggallery","offers":[{"title":"Default Title","offer_id":58886421152079,"sku":"VME02SPD","price":55.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0880\/2264\/7119\/files\/VME02SPD.jpg?v=1790345954","url":"https:\/\/www.thelightinggallery.co.uk\/products\/hager-consumer-unit-surge-protection-kit-type-2-vme02spd","provider":"thelightinggallery","version":"1.0","type":"link"}