{"product_id":"hager-mcb-1p-6ka-b-20a-1m-mtn120","title":"Hager MCB 1P 6kA B-20A 1M MTN120","description":"\u003ch2\u003eHager MTN116 16A Type B 1P Miniature Circuit Breaker\u003c\/h2\u003e\n\u003cp\u003eThe Hager MTN116 miniature circuit breaker provides overload and short-circuit protection for single-phase circuits. Its 16A Type B characteristic suits circuits with relatively low inrush current, while the compact one-module design conserves distribution-board space. Screw and bi-connect terminals, together with flexible 360° mounting, support straightforward installation.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16A Type B Protection:\u003c\/strong\u003e Designed for circuits with relatively low switching surges.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e6kA Breaking Capacity:\u003c\/strong\u003e Rated to IEC 60898-1 at 230V AC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Pole Design:\u003c\/strong\u003e Compact 1P breaker occupying one 17.5mm module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Connections:\u003c\/strong\u003e Screw top terminal and bi-connect bottom terminal accept rigid and flexible conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Operating Range:\u003c\/strong\u003e Suitable for operating temperatures from -25°C to 70°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Installation:\u003c\/strong\u003e Supports 360° mounting and uses a 35mm grid distance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%;\" border=\"1\" cellpadding=\"6\"\u003e\u003ctbody\u003e\n\u003ctr style=\"background-color: #e6e6e6;\"\u003e\u003cth colspan=\"2\"\u003eProduct Details\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel \/ SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMTN116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3250614343049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eElectrical\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Operational Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230–400 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBreaking Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA to IEC 60898-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Insulation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Impulse Withstand Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation at Rated Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.44 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnergy Limitation Class I²t\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eInstallation \u0026amp; Connections\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTop Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminal, aligned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBottom Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBi-connect, aligned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRigid Conductor Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlexible Conductor Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Tightening Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.80 Nm, top and bottom terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e360° Mounting Position\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGrid Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eSafety \u0026amp; Operating Conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2, according to IEC 60664 \/ IEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Humidity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor all climates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eDimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e83 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eTemperature Derating Data\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at -15°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e21.19 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at -10°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.89 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at -5°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.17 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 0°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.66 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 5°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 10°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.65 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 15°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18.14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 25°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17.13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 30°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 35°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.11 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 40°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 45°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 50°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 55°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.08 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 60°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.57 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 65°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.07 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current at 70°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.56 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e1 x Hager MTN116 16A Type B single-pole miniature circuit breaker\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eNeed help confirming compatibility with your distribution board or circuit? Contact The Lighting Gallery team before ordering and we’ll be happy to assist.\u003c\/p\u003e","brand":"thelightinggallery","offers":[{"title":"Default Title","offer_id":58862306001231,"sku":"MTN116","price":1.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0880\/2264\/7119\/files\/MTN116_0d6429fb-4814-406a-bd23-fe10b472684e.jpg?v=1790155480","url":"https:\/\/www.thelightinggallery.co.uk\/products\/hager-mcb-1p-6ka-b-20a-1m-mtn120","provider":"thelightinggallery","version":"1.0","type":"link"}