{"product_id":"hager-mcb-3p-6a-curve-c-15ka-icu-400v-10ka-icn-3-modules-ncn306a","title":"Hager MCB 3P 6A Curve C 15kA Icu 400V (10kA Icn) 3 Modules NCN306A","description":"\u003ch2\u003eHager NCN306A 3-Pole 6A Type C MCB\u003c\/h2\u003e\n\u003cp\u003eThe Hager NCN306A is a 3-pole miniature circuit breaker with a 6 A rated current and Type C curve. Designed for three-phase circuit protection, it provides overload and short-circuit protection at 400 V AC, with screw and biconnect terminals for practical modular installation.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3-pole protection:\u003c\/strong\u003e 3P configuration across three modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType C curve:\u003c\/strong\u003e Suitable for protecting three-phase distribution and motor\/control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBreaking capacity:\u003c\/strong\u003e 10 kA Icn at 400 V AC according to IEC 60898-1, with 15 kA Icu at 400 V AC according to IEC 60947-2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical rating:\u003c\/strong\u003e 6 A rated current, 400 V AC operating voltage and 50–60 Hz frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e Screw terminals with aligned top and bottom connections, plus biconnect compatibility at the bottom.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact modular format:\u003c\/strong\u003e Three modules wide, with IP20 protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color: #eeeeee;\"\u003e\u003cth colspan=\"2\"\u003eHager NCN306A Technical Data\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eElectrical\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current IN\u003c\/th\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1\u003c\/th\u003e\n\u003ctd\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated ultimate short-circuit breaking capacity Icu AC IEC 60947-2\u003c\/th\u003e\n\u003ctd\u003e15 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-2\u003c\/th\u003e\n\u003ctd\u003e15 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at -15°C\u003c\/th\u003e\n\u003ctd\u003e7.35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at -10°C\u003c\/th\u003e\n\u003ctd\u003e7.21 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at -5°C\u003c\/th\u003e\n\u003ctd\u003e7.07 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 0°C\u003c\/th\u003e\n\u003ctd\u003e6.93 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 5°C\u003c\/th\u003e\n\u003ctd\u003e6.78 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 10°C\u003c\/th\u003e\n\u003ctd\u003e6.63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 15°C\u003c\/th\u003e\n\u003ctd\u003e6.48 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 20°C\u003c\/th\u003e\n\u003ctd\u003e6.32 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 25°C\u003c\/th\u003e\n\u003ctd\u003e6.16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 30°C\u003c\/th\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 35°C\u003c\/th\u003e\n\u003ctd\u003e5.81 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 40°C\u003c\/th\u003e\n\u003ctd\u003e5.61 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 45°C\u003c\/th\u003e\n\u003ctd\u003e5.41 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 50°C\u003c\/th\u003e\n\u003ctd\u003e5.19 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 55°C\u003c\/th\u003e\n\u003ctd\u003e4.97 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 60°C\u003c\/th\u003e\n\u003ctd\u003e4.74 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 65°C\u003c\/th\u003e\n\u003ctd\u003e4.50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated current at 70°C\u003c\/th\u003e\n\u003ctd\u003e4.24 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated short-circuit breaking capacity Icn under 400 V AC according to IEC 60898-1\u003c\/th\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated service breaking capacity Ics AC according to IEC 60898-1\u003c\/th\u003e\n\u003ctd\u003e7.50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated ultimate short-circuit breaking capacity Icu under 230 V AC IEC 60947-2\u003c\/th\u003e\n\u003ctd\u003e30 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated short-circuit breaking capacity Icn AC according to IEC 60898-1\u003c\/th\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eArchitecture and Capacity\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType of pole\u003c\/th\u003e\n\u003ctd\u003e3P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCurve\u003c\/th\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNumber of modules\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eInstallation and Mounting\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal tightening torque top terminal\u003c\/th\u003e\n\u003ctd\u003e2.80 - 2.80 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal tightening torque down terminal\u003c\/th\u003e\n\u003ctd\u003e2.80 - 2.80 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal tightening torque\u003c\/th\u003e\n\u003ctd\u003e2.80 - 2.80 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType of bottom connection for modular devices\u003c\/th\u003e\n\u003ctd\u003ebiconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType of top connection for modular devices\u003c\/th\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003e360° mounting position possible\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eVoltage and Frequency\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated operational voltage Ue\u003c\/th\u003e\n\u003ctd\u003e400 - 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType voltage supply\u003c\/th\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRated impulse withstand voltage Uimp\u003c\/th\u003e\n\u003ctd\u003e6,000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFrequency\u003c\/th\u003e\n\u003ctd\u003e50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eConnection\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCross-section of input and output with screws, for massive conductors\u003c\/th\u003e\n\u003ctd\u003e1 - 35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCross-section of input and output with screws, for flexible conductors\u003c\/th\u003e\n\u003ctd\u003e1 - 25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCross-section of input with screws, for flexible conductors\u003c\/th\u003e\n\u003ctd\u003e1 - 25 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCross-section of input with screws, for massive conductors\u003c\/th\u003e\n\u003ctd\u003e1 - 35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eSafety and Use Conditions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eIngress Protection (IP) class\u003c\/th\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGrid distance\u003c\/th\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDegree of pollution according to IEC 60664 \/ IEC 60947-2\u003c\/th\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eClass of energy limitation I²t\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e-25 - 70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003ePower and Connectivity\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower dissipation at IN\u003c\/th\u003e\n\u003ctd\u003e4.06 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eType of connection\u003c\/th\u003e\n\u003ctd\u003eScrew terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTop connection alignment for modular devices\u003c\/th\u003e\n\u003ctd\u003eAligned terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDown connection alignment for modular devices\u003c\/th\u003e\n\u003ctd\u003eAligned terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eDimensions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd\u003e83 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd\u003e52.50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDepth\u003c\/th\u003e\n\u003ctd\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d9ead3;\"\u003e\u003cth colspan=\"2\"\u003eGeneral\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eEAN\u003c\/th\u003e\n\u003ctd\u003e3250614615795\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRoHS conform\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWhat's in the Box\u003c\/h3\u003e\n\u003cp\u003eHager NCN306A 3-pole 6 A Type C miniature circuit breaker. Accessories are not specified in the available product information.\u003c\/p\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse: collapse; width: 100%;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color: #eeeeee;\"\u003e\n\u003cth\u003eDocument\u003c\/th\u003e\n\u003cth\u003eFormat\u003c\/th\u003e\n\u003cth\u003eLink\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEP - MCB 1P 6kA B-16A, 1 module (English)\u003c\/td\u003e\n\u003ctd\u003ePDF\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/assets.hager.com\/step-content\/P\/HA_84320273\/Document\/std.lang.all\/PEP_HAGE-00928-V03.01-EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eREACH declaration NCN306A\u003c\/td\u003e\n\u003ctd\u003ePDF\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/assets.hager.com\/step-content\/P\/PRE_45269455EN\/Document\/std.lang.all\/reach_declaration_NCN306A_en-GB.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS report NCN306A\u003c\/td\u003e\n\u003ctd\u003ePDF\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/assets.hager.com\/step-content\/P\/PRO_45269455EN\/Document\/std.lang.all\/rohs_declaration_NCN306A_en-GB.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload PDF\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor help checking compatibility or selecting the right protective device, please contact thelightinggallery.\u003c\/p\u003e","brand":"thelightinggallery","offers":[{"title":"Default Title","offer_id":58878565155151,"sku":"NCN306A","price":24.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0880\/2264\/7119\/files\/NCN306A.jpg?v=1790333891","url":"https:\/\/www.thelightinggallery.co.uk\/products\/hager-mcb-3p-6a-curve-c-15ka-icu-400v-10ka-icn-3-modules-ncn306a","provider":"thelightinggallery","version":"1.0","type":"link"}