Hager RCBO 1P 20A 10kA Curve B 30mA Type A
The Hager RCBO 1M 1P B-20A Type A combines MCB and RCD protection in a single 1-module device. It safeguards circuits against overloads and short circuits with a 10kA breaking capacity, while providing 30mA Type A earth-leakage protection suitable for pulsed DC faults. Rated 20A with a B-curve, 230–240V, 50–60Hz, and IP20 protection, it is suitable for residential and light commercial use.
Key Features
- Combined protection: MCB and RCD protection against overload, short circuit, and earth leakage
- Rated current: 20A
- Residual operating current: 30mA
- Curve: B
- Residual current type: Type A
- Breaking capacity: 10kA
- Compact design: 1 module for DIN-rail installation
- Protection rating: IP20
Technical Specifications
| Product Details - Hager ADB420U | |
|---|---|
| Architecture | |
| Type of pole | 1P |
| Number of protected poles | 1 |
| Curve | B |
| Electrical Current | |
| Rated current IN | 20 A |
| Rated residual operating current Idn | 30 mA |
| Rated current at -25°C | 25.09 A |
| Rated current at -20°C | 24.63 A |
| Rated current at -15°C | 24.16 A |
| Rated current at -10°C | 23.70 A |
| Rated current at -5°C | 23.24 A |
| Rated current at 0°C | 22.78 A |
| Rated current at 5°C | 22.31 A |
| Rated current at 10°C | 21.85 A |
| Rated current at 15°C | 21.39 A |
| Rated current at 20°C | 20.93 A |
| Rated current at 25°C | 20.46 A |
| Rated current at 30°C | 20 A |
| Rated current at 35°C | 19.53 A |
| Rated current at 40°C | 19.05 A |
| Rated current at 50°C | 18.10 A |
| Rated current at 55°C | 17.63 A |
| Rated current at 60°C | 17.15 A |
| Min./max. threshold value of the AC thermal operation | 1.13 - 1.45 A |
| Safety | |
| Residual current type | A |
| Ingress Protection (IP) class | IP20 |
| Main Electrical Attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 10 kA |
| Voltage | |
| Rated insulation voltage Ui | 250 V |
| Rated impulse withstand voltage Uimp | 4,000 V |
| Rated operational voltage Ue | 230 - 240 V |
| Overvoltage category according to IEC 60947-1 | 3 |
| Power | |
| Power dissipation at IN | 6.50 W |
| Frequency | |
| Frequency | 50 - 60 Hz |
| Use Conditions | |
| Maximum altitude | 2,000 m |
| Class of energy limitation I²t | 3 |
| Operating temperature | -25 - 40 °C |
| Storage/transport temperature | -40 - 70 °C |
| Endurance | |
| Electrical endurance in number of cycles | 2,000 |
| Number of mechanical operations | 10,000 |
| Connection | |
| Cross-section of input with screws, for flexible conductors | 1 - 10 mm² |
| Cross-section of input with screws, for massive conductors | 1 - 16 mm² |
| Cross-section of input and output with screws, for flexible conductors | 1 - 16 mm² |
| Cross-section of input and output with screws, for massive conductors | 1 - 25 mm² |
| Cross-section of output with screws, for flexible conductors | 1 - 16 mm² |
| Cross-section of output with screws, for massive conductors | 1 - 25 mm² |
| Installation and Mounting | |
| Type of top connection for modular devices | Screw terminal |
| Type of bottom connection for modular devices | biconnect |
| Capacity | |
| Number of modules | 1 |
| Dimensions | |
| Height | 115 mm |
| Width | 17.80 mm |
| Depth | 70 mm |
| Compatibility | |
| Suitable for DIN rail | Yes |
Product Information
| Packaging and Identification | |
|---|---|
| EAN | 3250611036869 |
| Packaging | 1 piece |
Hager RCBO 1P 10A 10kA Curve B 30mA Type A
The Hager RCBO 1M 1P B-10A Type A combines MCB and RCD protection to guard circuits against overloads, short circuits, and earth leakage. With 10kA breaking capacity, 30mA Type A sensitivity, and a B-curve 10A rating, it suits residential and light commercial 230–240V, 50–60Hz circuits. Its slim 1-module design saves space on a DIN rail. Rated IP20 and suitable for operating temperatures from -25°C to 40°C.
Key Features
- Combined protection: MCB and RCD protection against overload, short circuit, and earth leakage
- Rated current: 10A
- Residual operating current: 30mA
- Curve: B
- Residual current type: Type A
- Breaking capacity: 10kA
- Compact design: 1 module for DIN-rail installation
- Protection rating: IP20
Technical Specifications
| Product Details - Hager ADB410U | |
|---|---|
| Architecture | |
| Type of pole | 1P |
| Number of protected poles | 1 |
| Curve | B |
| Electrical Current | |
| Rated current IN | 10 A |
| Rated residual operating current Idn | 30 mA |
| Rated current at -25°C | 13.30 A |
| Rated current at -20°C | 13 A |
| Rated current at -15°C | 12.70 A |
| Rated current at -10°C | 12.40 A |
| Rated current at -5°C | 12.10 A |
| Rated current at 0°C | 11.80 A |
| Rated current at 5°C | 11.50 A |
| Rated current at 10°C | 11.20 A |
| Rated current at 15°C | 10.90 A |
| Rated current at 20°C | 10.60 A |
| Rated current at 25°C | 10.30 A |
| Rated current at 30°C | 10 A |
| Rated current at 35°C | 9.75 A |
| Rated current at 40°C | 9.50 A |
| Rated current at 50°C | 9 A |
| Rated current at 55°C | 8.75 A |
| Rated current at 60°C | 8.50 A |
| Min./max. threshold value of the AC thermal operation | 1.13 - 1.45 A |
| Safety | |
| Residual current type | A |
| Ingress Protection (IP) class | IP20 |
| Main Electrical Attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 10 kA |
| Voltage | |
| Rated insulation voltage Ui | 250 V |
| Rated impulse withstand voltage Uimp | 4,000 V |
| Rated operational voltage Ue | 230 - 240 V |
| Overvoltage category according to IEC 60947-1 | 3 |
| Power | |
| Power dissipation at IN | 2.80 W |
| Frequency | |
| Frequency | 50 - 60 Hz |
| Use Conditions | |
| Maximum altitude | 2,000 m |
| Class of energy limitation I²t | 3 |
| Operating temperature | -25 - 40 °C |
| Storage/transport temperature | -40 - 70 °C |
| Endurance | |
| Electrical endurance in number of cycles | 2,000 |
| Number of mechanical operations | 10,000 |
| Connection | |
| Cross-section of input with screws, for flexible conductors | 1 - 10 mm² |
| Cross-section of input with screws, for massive conductors | 1 - 16 mm² |
| Cross-section of input and output with screws, for flexible conductors | 1 - 16 mm² |
| Cross-section of input and output with screws, for massive conductors | 1 - 25 mm² |
| Cross-section of output with screws, for flexible conductors | 1 - 16 mm² |
| Cross-section of output with screws, for massive conductors | 1 - 25 mm² |
| Installation and Mounting | |
| Type of top connection for modular devices | Screw terminal |
| Type of bottom connection for modular devices | biconnect |
| Capacity | |
| Number of modules | 1 |
| Dimensions | |
| Height | 115 mm |
| Width | 17.80 mm |
| Depth | 70 mm |
| Compatibility | |
| Suitable for DIN rail | Yes |
Product Information
| Packaging and Identification | |
|---|---|
| EAN | 3250611036838 |
| Packaging | 1 piece |
Hager RCBO 1P 6A 10kA Curve B 30mA Type A
The Hager RCBO 1M 1P 10kA B-6A Type A 30mA combines MCB and RCD protection to guard circuits against overloads, short circuits, and earth leakage. With 10kA breaking capacity and a B-curve for lighting and general loads, it suits residential and light commercial use. Its compact 1-module design saves space on a DIN rail. Rated 230–240V, 50–60Hz, with IP20 protection.
Key Features
- Combined protection: MCB and RCD protection against overload, short circuit, and earth leakage
- Rated current: 6A
- Residual operating current: 30mA
- Curve: B
- Residual current type: Type A
- Breaking capacity: 10kA
- Compact design: 1 module for DIN-rail installation
- Protection rating: IP20
Technical Specifications
| Product Details - Hager ADB406U | |
|---|---|
| Architecture | |
| Type of pole | 1P |
| Number of protected poles | 1 |
| Curve | B |
| Electrical Current | |
| Rated current IN | 6 A |
| Rated residual operating current Idn | 30 mA |
| Rated current at -25°C | 7.79 A |
| Rated current at -20°C | 7.63 A |
| Rated current at -15°C | 7.46 A |
| Rated current at -10°C | 7.30 A |
| Rated current at -5°C | 7.14 A |
| Rated current at 0°C | 6.98 A |
| Rated current at 5°C | 6.81 A |
| Rated current at 10°C | 6.65 A |
| Rated current at 15°C | 6.49 A |
| Rated current at 20°C | 6.33 A |
| Rated current at 25°C | 6.16 A |
| Rated current at 30°C | 6 A |
| Rated current at 35°C | 5.98 A |
| Rated current at 40°C | 5.95 A |
| Rated current at 50°C | 5.90 A |
| Rated current at 55°C | 5.88 A |
| Rated current at 60°C | 5.85 A |
| Min./max. threshold value of the AC thermal operation | 1.13 - 1.45 A |
| Safety | |
| Residual current type | A |
| Ingress Protection (IP) class | IP20 |
| Main Electrical Attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 10 kA |
| Voltage | |
| Rated insulation voltage Ui | 250 V |
| Rated impulse withstand voltage Uimp | 4,000 V |
| Rated operational voltage Ue | 230 - 240 V |
| Overvoltage category according to IEC 60947-1 | 3 |
| Power | |
| Power dissipation at IN | 2 W |
| Frequency | |
| Frequency | 50 - 60 Hz |
| Use Conditions | |
| Maximum altitude | 2,000 m |
| Class of energy limitation I²t | 3 |
| Operating temperature | -25 - 40 °C |
| Storage/transport temperature | -40 - 70 °C |
| Endurance | |
| Electrical endurance in number of cycles | 2,000 |
| Number of mechanical operations | 10,000 |
| Connection | |
| Cross-section of input with screws, for flexible conductors | 1 - 10 mm² |
| Cross-section of input with screws, for massive conductors | 1 - 16 mm² |
| Cross-section of input and output with screws, for flexible conductors | 1 - 16 mm² |
| Cross-section of input and output with screws, for massive conductors | 1 - 25 mm² |
| Cross-section of output with screws, for flexible conductors | 1 - 16 mm² |
| Cross-section of output with screws, for massive conductors | 1 - 25 mm² |
| Installation and Mounting | |
| Type of top connection for modular devices | Screw terminal |
| Type of bottom connection for modular devices | biconnect |
| Capacity | |
| Number of modules | 1 |
| Dimensions | |
| Height | 115 mm |
| Width | 17.80 mm |
| Depth | 70 mm |
| Compatibility | |
| Suitable for DIN rail | Yes |
Product Information
| Packaging and Identification | |
|---|---|
| EAN | 3250611036784 |
| Packaging | 1 piece |
Hager ADA110U 10A 10ka Type B RCBO RCBO 1P+N 6kA B-10A 30mA A Class ADA910U
£35.75
Unit price perHager ADA110U 10A 10ka Type B RCBO RCBO 1P+N 6kA B-10A 30mA A Class ADA910U
£35.75
Unit price perHager ADA910U 10A 1P+N RCBO
The Hager ADA910U 10A 1P+N RCBO combines a Type B curve with Type A residual current protection for 240V AC circuits. It provides 30mA residual operating current and 6kA short-circuit breaking capacity in a compact 2-module design.
Key Features
- Rated current: 10A
- Type B curve
- Type A residual current protection
- Residual operating current: 30mA
- Short-circuit breaking capacity: 6kA
- Pole configuration: 1P+N
- Protection rating: IP20
- Rated operational voltage: 240V AC
Technical Specifications
| Product Details - Hager ADA910U 10A 1P+N RCBO | |
|---|---|
| Electrical | |
| Rated current | 10A |
| Curve | Type B |
| Residual current protection | Type A |
| Residual operating current | 30mA |
| Short-circuit breaking capacity | 6kA |
| Pole configuration | 1P+N |
| Protection rating | IP20 |
| Rated operational voltage | 240V AC |
| Rated insulation voltage | 500V |
| Rated impulse withstand voltage | 4,000V |
| Frequency | 50Hz |
| Power dissipation at rated current | 3.40W |
| Electrical endurance | 2,000 cycles |
| Mechanical endurance | 2,000 operations |
| Installation and Connection | |
| Bottom connection | biconnect |
| Flexible conductor capacity | 1 to 16mm² |
| Rigid conductor capacity | 1 to 25mm² |
| Nominal terminal tightening torque | 2.10Nm |
| Maximum altitude | 2,000m |
| Operating temperature | -25°C to 40°C |
| Storage and transport temperature | -25°C to 70°C |
| Dimensions | |
| Height | 83mm |
| Width | 35mm |
| Depth | 68mm |
| Number of modules | 2 |
| General | |
| Environmental compliance | RoHS compliant |