Hager 10 Way HI Integrity Configurable 100A Switch 2*100A 30mA RCCB Round KO VML910CURK
Hager 10 Way HI Integrity Configurable 100A Switch 2*100A 30mA RCCB Round KO VML910CURK
Hager VML120RK 20-Way 100A Metal-Clad Consumer Unit
The Hager VML120RK is a surface-mounted, metal-clad consumer unit with a 100 A switch disconnector incomer and 20 outgoing ways. It is supplied with a full metal DIN rail, earth and neutral terminals, busbar, marking labels and installation instructions for a practical distribution-board installation.
Key Features
- 20-way consumer unit: Provides 20 outgoing ways in a metal-clad enclosure.
- 100 A isolator incomer: Fitted with a 100 A switch disconnector incoming device.
- Complete installation set: Supplied with metal DIN rail, busbar, earth and neutral terminals, marking labels and instructions.
- Surface mounting: Designed for surface installation with a top-hinged door.
- Construction: Metal-clad enclosure with IP2XC protection.
- Compliance: Complies with BS EN 61439-3 Annex ZB and BS EN 61439.
- Surge protection: Surge protection is not fitted and the unit is not marked as surge-protection ready.
Technical Specifications
| Hager VML120RK Technical Data | |
|---|---|
| Electrical and Capacity | |
| Current rating | 100 A |
| Incoming device | 100 A Isolator |
| Number of outgoing ways | 20 |
| Product range | Switch Disconnector |
| Surge protection fitted | No |
| Surge protection ready | No |
| Construction and Installation | |
| Product type | Enclosure |
| Mounting | Surface |
| Door type | Top hinged |
| Supplied equipment | Full metal DIN rail, earth and neutral terminals, marking labels, busbar and instructions |
| Packaging type | Each |
| Dimensions and Weight | |
| Height | 245 mm |
| Width | 297 mm |
| Depth | 100 mm |
| Dimensions | (H) 245 mm × (W) 297 mm × (D) 100 mm |
| Weight | 2.6 kg |
| Protection and Standards | |
| IP rating | IP2XC |
| Standards | BS EN 61439 |
| Compliance | BS EN 61439-3 Annex ZB |
| General | |
| Guarantee | 1 Year |
| UNSPSC V18 | 39121110 |
| UNSPSC V24 | 39121110 |
What's in the Box
Hager VML120RK metal-clad consumer unit with full metal DIN rail, 100 A switch disconnector incomer, earth and neutral terminals, busbar, marking labels and installation instructions.
Downloads
No confirmed technical document link is currently available for this product. Add the relevant Hager technical document when available.
For help checking board compatibility, outgoing ways or installation requirements, please contact thelightinggallery.
Hager VML120RK 20 Way 100A Isolator Incomer Metal Clad Consumer Unit
Hager VML120RK 20 Way 100A Isolator Incomer Metal Clad Consumer Unit
Hager VML120RK 20-Way 100A Metal-Clad Consumer Unit
The Hager VML120RK is a surface-mounted, metal-clad consumer unit with a 100 A switch disconnector incomer and 20 outgoing ways. It is supplied with a full metal DIN rail, earth and neutral terminals, busbar, marking labels and installation instructions for a practical distribution-board installation.
Key Features
- 20-way consumer unit: Provides 20 outgoing ways in a metal-clad enclosure.
- 100 A isolator incomer: Fitted with a 100 A switch disconnector incoming device.
- Complete installation set: Supplied with metal DIN rail, busbar, earth and neutral terminals, marking labels and instructions.
- Surface mounting: Designed for surface installation with a top-hinged door.
- Construction: Metal-clad enclosure with IP2XC protection.
- Compliance: Complies with BS EN 61439-3 Annex ZB and BS EN 61439.
- Surge protection: Surge protection is not fitted and the unit is not marked as surge-protection ready.
Technical Specifications
| Hager VML120RK Technical Data | |
|---|---|
| Electrical and Capacity | |
| Current rating | 100 A |
| Incoming device | 100 A Isolator |
| Number of outgoing ways | 20 |
| Product range | Switch Disconnector |
| Surge protection fitted | No |
| Surge protection ready | No |
| Construction and Installation | |
| Product type | Enclosure |
| Mounting | Surface |
| Door type | Top hinged |
| Supplied equipment | Full metal DIN rail, earth and neutral terminals, marking labels, busbar and instructions |
| Packaging type | Each |
| Dimensions and Weight | |
| Height | 245 mm |
| Width | 297 mm |
| Depth | 100 mm |
| Dimensions | (H) 245 mm × (W) 297 mm × (D) 100 mm |
| Weight | 2.6 kg |
| Protection and Standards | |
| IP rating | IP2XC |
| Standards | BS EN 61439 |
| Compliance | BS EN 61439-3 Annex ZB |
| General | |
| Guarantee | 1 Year |
| UNSPSC V18 | 39121110 |
| UNSPSC V24 | 39121110 |
What's in the Box
Hager VML120RK metal-clad consumer unit with full metal DIN rail, 100 A switch disconnector incomer, earth and neutral terminals, busbar, marking labels and installation instructions.
Downloads
No confirmed technical document link is currently available for this product. Add the relevant Hager technical document when available.
For help checking board compatibility, outgoing ways or installation requirements, please contact thelightinggallery.
Hager VML114RK 14 Way 100A Isolator Incomer Metal Clad Consumer Unit
Hager VML114RK 14 Way 100A Isolator Incomer Metal Clad Consumer Unit
Hager VML114RK 14-Way 100A Metal-Clad Consumer Unit
The Hager VML114RK is a surface-mounted, metal-clad consumer unit with a 100 A switch disconnector incomer and 14 outgoing ways. It is supplied with a full metal DIN rail, earth and neutral terminals, busbar, marking labels and installation instructions for a practical distribution-board installation.
Key Features
- 14-way consumer unit: Provides 14 outgoing ways in a metal-clad enclosure.
- 100 A isolator incomer: Fitted with a 100 A switch disconnector incoming device.
- Complete installation set: Supplied with metal DIN rail, busbar, earth and neutral terminals, marking labels and instructions.
- Surface mounting: Designed for surface installation with a top-hinged door.
- Construction: Metal-clad enclosure with IP2XC protection.
- Compliance: Complies with BS EN 61439-3 Annex ZB and BS EN 61439.
- Surge protection: Surge protection is not fitted and the unit is not marked as surge-protection ready.
Technical Specifications
| Hager VML114RK Technical Data | |
|---|---|
| Electrical and Capacity | |
| Current rating | 100 A |
| Incoming device | 100 A Isolator |
| Number of outgoing ways | 14 |
| Product range | Switch Disconnector |
| Surge protection fitted | No |
| Surge protection ready | No |
| Construction and Installation | |
| Product type | Enclosure |
| Mounting | Surface |
| Door type | Top hinged |
| Supplied equipment | Full metal DIN rail, earth and neutral terminals, marking labels, busbar and instructions |
| Packaging type | Each |
| Dimensions and Weight | |
| Height | 245 mm |
| Width | 297 mm |
| Depth | 100 mm |
| Dimensions | (H) 245 mm × (W) 297 mm × (D) 100 mm |
| Weight | 2.6 kg |
| Protection and Standards | |
| IP rating | IP2XC |
| Standards | BS EN 61439 |
| Compliance | BS EN 61439-3 Annex ZB |
| General | |
| Guarantee | 1 Year |
| UNSPSC V18 | 39121110 |
| UNSPSC V24 | 39121110 |
What's in the Box
Hager VML114RK metal-clad consumer unit with full metal DIN rail, 100 A switch disconnector incomer, earth and neutral terminals, busbar, marking labels and installation instructions.
Downloads
No confirmed technical document link is currently available for this product. Add the relevant Hager technical document when available.
For help checking board compatibility, outgoing ways or installation requirements, please contact thelightinggallery.
Hager VME106 6-Way 100A Metal-Clad Consumer Unit
The Hager VME106 is a surface-mounted, metal-clad consumer unit with a 100 A switch disconnector incomer and six outgoing ways. It is supplied with a full metal DIN rail, earth and neutral terminals, busbar, marking labels and installation instructions for a practical distribution-board installation.
Key Features
- 6-way consumer unit: Provides six outgoing ways in a compact metal-clad enclosure.
- 100 A isolator incomer: Fitted with a 100 A switch disconnector incoming device.
- Complete installation set: Supplied with metal DIN rail, busbar, earth and neutral terminals, marking labels and instructions.
- Surface mounting: Designed for surface installation with a top-hinged door.
- Construction: Metal-clad enclosure with IP2XC protection.
- Compliance: Complies with BS EN 61439-3 Annex ZB and BS EN 61439.
- Surge protection: Surge protection is not fitted and the unit is not marked as surge-protection ready.
Technical Specifications
| Hager VME106 Technical Data | |
|---|---|
| Electrical and Capacity | |
| Current rating | 100 A |
| Incoming device | 100 A Isolator |
| Number of outgoing ways | 6 |
| Product range | Switch Disconnector |
| Surge protection fitted | No |
| Surge protection ready | No |
| Construction and Installation | |
| Product type | Enclosure |
| Mounting | Surface |
| Door type | Top hinged |
| Supplied equipment | Full metal DIN rail, earth and neutral terminals, marking labels, busbar and instructions |
| Packaging type | Each |
| Dimensions and Weight | |
| Height | 240 mm |
| Width | 240 mm |
| Depth | 102.5 mm |
| Dimensions | (H) 240 mm × (W) 221 mm × (D) 102.5 mm |
| Weight | 2.6 kg |
| Protection and Standards | |
| IP rating | IP2XC |
| Standards | BS EN 61439 |
| Compliance | BS EN 61439-3 Annex ZB |
| General | |
| Guarantee | 1 Year |
| UNSPSC V18 | 39121110 |
| UNSPSC V24 | 39121110 |
What's in the Box
Hager VME106 metal-clad consumer unit with full metal DIN rail, 100 A switch disconnector incomer, earth and neutral terminals, busbar, marking labels and installation instructions.
Downloads
No confirmed technical document link is currently available for this product. Add the relevant Hager technical document when available.
For help checking board compatibility, outgoing ways or installation requirements, please contact thelightinggallery.
Hager VML110RK 10 Way 100A Isolator Incomer Metal Clad Consumer Unit
Hager VML110RK 10 Way 100A Isolator Incomer Metal Clad Consumer Unit
Hager VML110RK 10-Way 100A Metal-Clad Consumer Unit
The Hager VML110RK is a surface-mounted, metal-clad consumer unit with a 100 A switch disconnector incomer and 10 outgoing ways. It is supplied with a full metal DIN rail, earth and neutral terminals, busbar, marking labels and installation instructions, making it a practical enclosure solution for residential and light commercial distribution installations.
Key Features
- 10-way consumer unit: Provides 10 outgoing ways within a compact metal-clad enclosure.
- 100 A isolator incomer: Fitted with a 100 A switch disconnector incoming device.
- Complete installation set: Supplied with metal DIN rail, busbar, earth and neutral terminals, marking labels and instructions.
- Surface mounting: Designed for surface installation with a top-hinged door.
- Construction: Metal-clad enclosure with IP2XC protection.
- Compliance: Complies with BS EN 61439-3 Annex ZB and BS EN 61439.
- Surge protection: Surge protection is not fitted and the unit is not marked as surge-protection ready.
Technical Specifications
| Hager VML110RK Technical Data | |
|---|---|
| Electrical and Capacity | |
| Current rating | 100 A |
| Incoming device | 100 A Isolator |
| Number of outgoing ways | 10 |
| Product range | Switch Disconnector |
| Surge protection fitted | No |
| Surge protection ready | No |
| Construction and Installation | |
| Product type | Enclosure |
| Mounting | Surface |
| Door type | Top hinged |
| Supplied equipment | Full metal DIN rail, earth and neutral terminals, marking labels, busbar and instructions |
| Packaging type | Each |
| Dimensions and Weight | |
| Height | 245 mm |
| Width | 297 mm |
| Depth | 100 mm |
| Dimensions | (H) 245 mm × (W) 297 mm × (D) 100 mm |
| Weight | 2.6 kg |
| Protection and Standards | |
| IP rating | IP2XC |
| Standards | BS EN 61439 |
| Compliance | BS EN 61439-3 Annex ZB |
| General | |
| Guarantee | 1 Year |
| UNSPSC V18 | 39121110 |
| UNSPSC V24 | 39121110 |
What's in the Box
Hager VML110RK metal-clad consumer unit with full metal DIN rail, 100 A switch disconnector incomer, earth and neutral terminals, busbar, marking labels and installation instructions.
Downloads
No confirmed technical document link is currently available for this product. Add the relevant Hager technical document when available.
For help checking board compatibility, outgoing ways or installation requirements, please contact thelightinggallery.
Hager VME02SPD Type 2 Surge Protection Kit
The Hager VME02SPD is a Type 2 surge protection kit for consumer units and distribution boards. It provides voltage-limiting protection for TN and TT networks, with a 275 V continuous operating voltage, 1.35 kV voltage protection level and optical disconnector indication. Its built-in installation format is designed for indoor use.
Key Features
- Type 2 surge protection: IEC 61643 requirement class T2 for protecting electrical installations against transient overvoltage.
- Voltage-limiting design: 275 V continuous operating voltage Uc and 1.35 kV protection level Up.
- Discharge performance: 40 kA maximum discharge current, 20 kA nominal discharge current and 25 kA short-circuit current rating.
- Network compatibility: Designed for TN and TT network configurations, with L-N and L-PEN protection modes.
- Installation: Built-in installation for indoor use with optical disconnector indication.
- Protection and durability: IP20 enclosure, operating temperature from -40 to 80°C and maximum altitude of 2,000 m.
Technical Specifications
| Hager VME02SPD Technical Data | |
|---|---|
| Voltage | |
| Reference test voltage Utest AC | 255 V |
| Overvoltage category according to IEC 60947-1 | 3 |
| Type voltage supply | AC |
| Continuous operating voltage Uc according to IEC 61643-1 | 275 V |
| Voltage protection level Up according to IEC 61643-1 | 1.35 kV |
| Nominal voltage | 240 V AC ± 10 % |
| Mode of protection design | Voltage-limiting type |
| Equipment and Use Conditions | |
| With remote signalling contact | No |
| Operating temperature | -40 - 80 °C |
| Maximum altitude | 2,000 m |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 2 |
| Storage/transport temperature | -40 - 80 °C |
| Air humidity protection | 5 - 95% |
| Standards and Frequency | |
| Requirement class IEC 61643 | T2 |
| Frequency | 50 - 60 Hz |
| Dimensions and Connectivity | |
| Height | 95 mm |
| Width | 100 mm |
| Depth | 240 mm |
| Mounting type | Built in installation |
| Electrical and Discharge Performance | |
| Short-circuit current rating (Isccr) | 25 kA |
| Maximum discharge current (Imax) | 40 kA |
| Maximum overcurrent protection device, parallel connection (fuse) | 125 A |
| Nominal discharge current In | 20 kA |
| Functions and Installation | |
| Disconnector indication | Optical |
| Suitable for indoor usage | Yes |
| Safety | |
| Mode of protection | L-N, L-PEN |
| TOV behaviour at UT | 350 V AC (5 s / withstand mode), 460 V AC (120 min / safe failure mode) |
| Ingress Protection (IP) class | IP20 |
| Materials and Network | |
| Material | Polyamide (PA) |
| Colour | Light grey |
| RAL code | 7035 |
| Network type | TN, TT |
| General | |
| EAN shown in existing product description | 5015652608714 |
| Current product barcode | 5015652606444 |
| RoHS conform | Yes |
What's in the Box
Hager VME02SPD Type 2 surge protection kit. Additional accessories are not specified in the available product information.
Downloads
| Document | Format | Link |
|---|---|---|
| PEP - 12 Way 100A Metal Customer Unit Round KO + T2 SPD (English) | Download PDF | |
| REACH declaration VME02SPD | Download PDF | |
| Hager RoHS report VME02SPD | Download PDF |
For help checking compatibility or selecting the right surge protection device, please contact thelightinggallery.
Hager VM02SPD Type 2 Surge Protection Kit
The Hager VM02SPD is a Type 2 surge protection kit for consumer units and distribution boards. Designed for TN-S and TT networks, it provides protection between line and neutral and between neutral and protective earth, with a 275 V continuous operating voltage, optical disconnector indication and DIN rail mounting.
Key Features
- Type 2 surge protection: IEC 61643 requirement class T2 for protecting electrical installations against transient overvoltage.
- Compact format: Two modules wide for installation in a consumer unit or distribution board.
- Discharge performance: Maximum discharge current of 15 kA for L-N (PEN) and 40 kA for N-PE.
- Voltage protection: Protection level Up of 1 kV for L-N (PEN) and 1,500 V for N-PE.
- Network compatibility: Suitable for TN-S and TT network configurations.
- Installation: DIN rail mounting with screw connections and optical disconnector indication.
- Protection and durability: IP20 enclosure, Class II insulation and operating temperature from -40 to 60°C.
Technical Specifications
| Hager VM02SPD Technical Data | |
|---|---|
| Capacity | |
| Number of modules | 2 |
| Voltage | |
| Continuous operating voltage Uc according to IEC 61643-1 | 275 V |
| Voltage protection level Up according to IEC 61643-1 | 1 kV |
| Voltage protection level Up N-PE IEC 61643-11 | 1,500 V |
| Voltage protection level Up L-N (PEN) | 1 kV |
| Type voltage supply | AC |
| Nominal voltage | 240 V AC ± 10 % |
| Electrical and Discharge Performance | |
| Maximum overcurrent protection device, parallel connection (fuse) | 125 A |
| Maximum discharge current (Imax) | 15 kA |
| Maximum discharge current (Imax) L-N (PEN) | 15 kA |
| Maximum discharge current (Imax) N-PE | 40 kA |
| Nominal discharge current In | 20 kA |
| Nominal discharge current In 8 - 20 µs L-N (PEN) | 5 kA |
| Nominal discharge current In 8 - 20 µs N-PE | 20 kA |
| Follow current interrupting rating | 0.1 kA |
| Short-circuit current rating (Isccr) | 50 kA |
| Residual current Ipe | < 5 μA |
| Dimensions | |
| Height | 90 mm |
| Width | 100 mm |
| Depth | 170 mm |
| Safety | |
| Ingress Protection (IP) class | IP20 |
| Protection class | Isolation class II |
| TOV behaviour at UT (N-PE) | 1200 V AC (200 ms / withstand mode) |
| Mode of protection | L-N, N-PE |
| TOV behaviour at UT (L-N) | 350 V AC (5 s / withstand mode) |
| Use Conditions | |
| Operating temperature | -40 - 60 °C |
| Air humidity protection | 5 - 95% |
| Storage/transport temperature | -40 - 80 °C |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 2 |
| Maximum altitude | 2,000 m |
| Materials | |
| Product colour | Light grey |
| RAL code | 7035 |
| Material | Thermoplastic |
| Network Configuration | |
| Network type | TN-S, TT |
| Network TN | No |
| Network TN-C | No |
| Network DC | No |
| Network IT | No |
| Network TT | Yes |
| Network TN-C-S | No |
| Network TN-S | Yes |
| Equipment | |
| With remote signalling contact | No |
| Rated load current IL | 80 A |
| Connection | |
| Cross-section for rigid conductor, for protective conductor | 1.5 - 35 mm² |
| Cross-section for flexible conductor, for protective conductor | 1.5 - 25 mm² |
| Cross-section flexible conductor | 1.5 - 25 mm² |
| Cross-section rigid conductor | 1.5 - 35 mm² |
| Connector/plug type | Screw terminal |
| Number of connections | 1 |
| Standards and Frequency | |
| Requirement class IEC 61643 | T2 |
| Frequency | 50 - 60 Hz |
| Installation and Architecture | |
| Nominal tightening torque | 3.6 - 3.6 Nm |
| Suitable for indoor usage | Yes |
| Type of pole | 2P+T |
| Neutral position | Left |
| Connectivity and Functions | |
| Mounting type | DIN rail |
| Type of connection | Screw connection |
| Disconnector indication | Optical |
| Fuse | |
| Fuse characteristics | gG |
| General | |
| Barcode | 5015652606444 |
| RoHS conform | Yes |
| REACh-SVHC free | Yes |
| Halogen free | Yes |
What's in the Box
Hager VM02SPD Type 2 surge protection kit. Additional accessories are not specified in the available product information.
Downloads
| Document | Format | Link |
|---|---|---|
| REACH declaration VM02SPD | Download PDF | |
| RoHS report VM02SPD | Download PDF |
For help checking compatibility or selecting the right surge protection device, please contact thelightinggallery.
Hager NCN340A 3-Pole 40A Type C MCB
The Hager NCN340A is a 3-pole miniature circuit breaker with a 40 A rated current and Type C curve. It provides reliable three-phase protection against overload and short circuits in commercial and light industrial distribution boards. Rated at 400 V AC, it combines a compact three-module format with screw and biconnect terminals for practical installation.
Key Features
- 3-pole protection: 3P configuration across three modules.
- Type C curve: Suitable for three-phase commercial and light industrial distribution.
- Breaking capacity: 10 kA Icn at 400 V AC according to IEC 60898-1, with 15 kA Icu at 400 V AC and 30 kA Icu at 230 V AC according to IEC 60947-2.
- Electrical rating: 40 A rated current, 400 V AC operating voltage and 50–60 Hz frequency.
- Connection: Screw and biconnect terminals accepting conductors from 1–35 mm², with aligned top and bottom connections.
- Compact modular format: Three modules wide, with IP20 protection and 360° mounting possible.
- Endurance: 20,000 mechanical operations and 4,000 electrical operations.
Technical Specifications
| Hager NCN340A Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 40 A |
| Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 | 20 kA |
| Rated ultimate short-circuit breaking capacity Icu AC IEC 60947-2 | 15 kA |
| Rated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-2 | 15 kA |
| Rated current at 30°C | 40 A |
| Rated short-circuit breaking capacity Icn under 400 V AC according to IEC 60898-1 | 10 kA |
| Rated service breaking capacity Ics AC according to IEC 60898-1 | 7.50 kA |
| Rated ultimate short-circuit breaking capacity Icu under 230 V AC IEC 60947-2 | 30 kA |
| Architecture and Capacity | |
| Type of pole | 3P |
| Curve | C |
| Number of modules | 3 |
| Installation and Mounting | |
| Nominal tightening torque top terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque down terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque | 2.80 - 2.80 Nm |
| Type of bottom connection for modular devices | biconnect |
| Type of top connection for modular devices | Screw terminal |
| 360° mounting position possible | Yes |
| Mechanical endurance | 20,000 operations |
| Electrical endurance | 4,000 operations |
| Voltage and Frequency | |
| Rated operational voltage Ue | 400 - 400 V |
| Type voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6,000 V |
| Frequency | 50 - 60 Hz |
| Connection | |
| Cross-section of input and output with screws, for massive conductors | 1 - 35 mm² |
| Cross-section of input and output with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for massive conductors | 1 - 35 mm² |
| Safety and Use Conditions | |
| Ingress Protection (IP) class | IP20 |
| Grid distance | 60 mm |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 2 |
| Class of energy limitation I²t | 3 |
| Operating temperature | -25 - 70 °C |
| Power and Connectivity | |
| Power dissipation at IN | 10.10 W |
| Type of connection | Screw terminal |
| Top connection alignment for modular devices | Aligned terminal |
| Down connection alignment for modular devices | Aligned terminal |
| Dimensions | |
| Height | 83 mm |
| Width | 52.50 mm |
| Depth | 70 mm |
| General | |
| EAN | 3250614615863 |
| RoHS conform | Yes |
What's in the Box
Hager NCN340A 3-pole 40 A Type C miniature circuit breaker. Accessories are not specified in the available product information.
Downloads
| Document | Format | Link |
|---|---|---|
| PEP - MCB 1P 6kA B-16A, 1 module (English) | Download PDF | |
| REACH declaration NCN340A | Download PDF | |
| RoHS report NCN340A | Download PDF |
For help checking compatibility or selecting the right protective device, please contact thelightinggallery.
Hager NCN332A 3-Pole 32A Type C MCB
The Hager NCN332A is a 3-pole miniature circuit breaker with a 32 A rated current and Type C curve. It provides reliable three-phase protection against overload and short circuits in residential and commercial distribution boards. Rated at 400 V AC, it combines a compact three-module format with screw and biconnect terminals for practical installation.
Key Features
- 3-pole protection: 3P configuration across three modules.
- Type C curve: Suitable for three-phase distribution and commercial applications.
- Breaking capacity: 10 kA Icn at 400 V AC according to IEC 60898-1, with 15 kA Icu at 400 V AC and 30 kA Icu at 230 V AC according to IEC 60947-2.
- Electrical rating: 32 A rated current, 400 V AC operating voltage and 50–60 Hz frequency.
- Connection: Screw and biconnect terminals accepting conductors from 1–35 mm², with aligned top and bottom connections.
- Compact modular format: Three modules wide, with IP20 protection and 360° mounting possible.
- Endurance: 20,000 mechanical operations and 4,000 electrical operations.
Technical Specifications
| Hager NCN332A Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 32 A |
| Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 | 20 kA |
| Rated ultimate short-circuit breaking capacity Icu AC IEC 60947-2 | 15 kA |
| Rated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-2 | 15 kA |
| Rated current at -15°C | 37.86 A |
| Rated current at -10°C | 37.25 A |
| Rated current at -5°C | 36.64 A |
| Rated current at 0°C | 36.01 A |
| Rated current at 5°C | 35.37 A |
| Rated current at 10°C | 34.73 A |
| Rated current at 15°C | 34.06 A |
| Rated current at 20°C | 33.39 A |
| Rated current at 25°C | 32.70 A |
| Rated current at 30°C | 32 A |
| Rated current at 35°C | 31.26 A |
| Rated current at 40°C | 30.50 A |
| Rated current at 45°C | 29.72 A |
| Rated current at 50°C | 28.92 A |
| Rated current at 55°C | 28.10 A |
| Rated current at 60°C | 27.26 A |
| Rated current at 65°C | 26.38 A |
| Rated current at 70°C | 25.48 A |
| Rated short-circuit breaking capacity Icn under 400 V AC according to IEC 60898-1 | 10 kA |
| Rated service breaking capacity Ics AC according to IEC 60898-1 | 7.50 kA |
| Rated ultimate short-circuit breaking capacity Icu under 230 V AC IEC 60947-2 | 30 kA |
| Architecture and Capacity | |
| Type of pole | 3P |
| Curve | C |
| Number of modules | 3 |
| Installation and Mounting | |
| Nominal tightening torque top terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque down terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque | 2.80 - 2.80 Nm |
| Type of bottom connection for modular devices | biconnect |
| Type of top connection for modular devices | Screw terminal |
| 360° mounting position possible | Yes |
| Mechanical endurance | 20,000 operations |
| Electrical endurance | 4,000 operations |
| Voltage and Frequency | |
| Rated operational voltage Ue | 400 - 400 V |
| Type voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6,000 V |
| Frequency | 50 - 60 Hz |
| Connection | |
| Cross-section of input and output with screws, for massive conductors | 1 - 35 mm² |
| Cross-section of input and output with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for massive conductors | 1 - 35 mm² |
| Safety and Use Conditions | |
| Ingress Protection (IP) class | IP20 |
| Grid distance | 60 mm |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 2 |
| Class of energy limitation I²t | 3 |
| Operating temperature | -25 - 70 °C |
| Power and Connectivity | |
| Power dissipation at IN | 12.30 W |
| Type of connection | Screw terminal |
| Top connection alignment for modular devices | Aligned terminal |
| Down connection alignment for modular devices | Aligned terminal |
| Dimensions | |
| Height | 83 mm |
| Width | 52.50 mm |
| Depth | 70 mm |
| General | |
| EAN | 3250614615856 |
| RoHS conform | Yes |
What's in the Box
Hager NCN332A 3-pole 32 A Type C miniature circuit breaker. Accessories are not specified in the available product information.
Downloads
| Document | Format | Link |
|---|---|---|
| PEP - MCB 1P 6kA B-16A, 1 module (English) | Download PDF | |
| REACH declaration NCN332A | Download PDF | |
| RoHS report NCN332A | Download PDF |
For help checking compatibility or selecting the right protective device, please contact thelightinggallery.
Hager NCN320A 3-Pole 20A Type C MCB
The Hager NCN320A is a 3-pole miniature circuit breaker with a 20 A rated current and Type C curve. It provides reliable three-phase protection against overload and short circuits in residential and light commercial distribution boards. Rated at 400 V AC, it combines a compact three-module format with screw and biconnect terminals for practical installation.
Key Features
- 3-pole protection: 3P configuration across three modules.
- Type C curve: Suitable for three-phase distribution and light commercial applications.
- Breaking capacity: 10 kA Icn at 400 V AC according to IEC 60898-1, with 15 kA Icu at 400 V AC and 30 kA Icu at 230 V AC according to IEC 60947-2.
- Electrical rating: 20 A rated current, 400 V AC operating voltage and 50–60 Hz frequency.
- Connection: Screw and biconnect terminals accepting conductors from 1–35 mm², with aligned top and bottom connections.
- Compact modular format: Three modules wide, with IP20 protection and 360° mounting possible.
- Endurance: 20,000 mechanical operations and 4,000 electrical operations.
Technical Specifications
| Hager NCN320A Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 20 A |
| Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 | 20 kA |
| Rated ultimate short-circuit breaking capacity Icu AC IEC 60947-2 | 15 kA |
| Rated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-2 | 15 kA |
| Rated current at -15°C | 23.98 A |
| Rated current at -10°C | 23.57 A |
| Rated current at -5°C | 23.16 A |
| Rated current at 0°C | 22.73 A |
| Rated current at 5°C | 22.30 A |
| Rated current at 10°C | 21.86 A |
| Rated current at 15°C | 21.41 A |
| Rated current at 20°C | 20.95 A |
| Rated current at 25°C | 20.48 A |
| Rated current at 30°C | 20 A |
| Rated current at 35°C | 19.48 A |
| Rated current at 40°C | 18.94 A |
| Rated current at 45°C | 18.39 A |
| Rated current at 50°C | 17.81 A |
| Rated current at 55°C | 17.22 A |
| Rated current at 60°C | 16.61 A |
| Rated current at 65°C | 15.98 A |
| Rated current at 70°C | 15.32 A |
| Rated short-circuit breaking capacity Icn under 400 V AC according to IEC 60898-1 | 10 kA |
| Rated service breaking capacity Ics AC according to IEC 60898-1 | 7.50 kA |
| Rated ultimate short-circuit breaking capacity Icu under 230 V AC IEC 60947-2 | 30 kA |
| Architecture and Capacity | |
| Type of pole | 3P |
| Curve | C |
| Number of modules | 3 |
| Installation and Mounting | |
| Nominal tightening torque top terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque down terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque | 2.80 - 2.80 Nm |
| Type of bottom connection for modular devices | biconnect |
| Type of top connection for modular devices | Screw terminal |
| 360° mounting position possible | Yes |
| Mechanical endurance | 20,000 operations |
| Electrical endurance | 4,000 operations |
| Voltage and Frequency | |
| Rated operational voltage Ue | 400 - 400 V |
| Type voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6,000 V |
| Frequency | 50 - 60 Hz |
| Connection | |
| Cross-section of input and output with screws, for massive conductors | 1 - 35 mm² |
| Cross-section of input and output with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for massive conductors | 1 - 35 mm² |
| Safety and Use Conditions | |
| Ingress Protection (IP) class | IP20 |
| Grid distance | 60 mm |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 2 |
| Class of energy limitation I²t | 3 |
| Operating temperature | -25 - 70 °C |
| Power and Connectivity | |
| Power dissipation at IN | 8.04 W |
| Type of connection | Screw terminal |
| Top connection alignment for modular devices | Aligned terminal |
| Down connection alignment for modular devices | Aligned terminal |
| Dimensions | |
| Height | 83 mm |
| Width | 52.50 mm |
| Depth | 70 mm |
| General | |
| EAN | 3250614615832 |
| RoHS conform | Yes |
What's in the Box
Hager NCN320A 3-pole 20 A Type C miniature circuit breaker. Accessories are not specified in the available product information.
Downloads
| Document | Format | Link |
|---|---|---|
| PEP - MCB 1P 6kA B-16A, 1 module (English) | Download PDF | |
| REACH declaration NCN320A | Download PDF | |
| RoHS report NCN320A | Download PDF |
For help checking compatibility or selecting the right protective device, please contact thelightinggallery.
Hager Miniature Circuit Breaker 3P 16A C-curve 10kA Icn, 15kA Icu 400V 3M NCN316A
Hager Miniature Circuit Breaker 3P 16A C-curve 10kA Icn, 15kA Icu 400V 3M NCN316A
Hager NCN316A 3-Pole 16A Type C MCB
The Hager NCN316A is a 3-pole miniature circuit breaker with a 16 A rated current and Type C curve. It provides reliable three-phase protection against overload and short circuits in residential and light commercial panels. Rated at 400 V AC, it combines a compact three-module format with screw and biconnect terminals for practical installation.
Key Features
- 3-pole protection: 3P configuration across three modules.
- Type C curve: Suitable for three-phase distribution and light commercial applications.
- Breaking capacity: 10 kA Icn at 400 V AC according to IEC 60898-1, with 15 kA Icu at 400 V AC and 30 kA Icu at 230 V AC according to IEC 60947-2.
- Electrical rating: 16 A rated current, 400 V AC operating voltage and 50–60 Hz frequency.
- Connection: Screw and biconnect terminals accepting conductors from 1–35 mm², with aligned top and bottom connections.
- Compact modular format: Three modules wide, with IP20 protection and 360° mounting possible.
- Endurance: 20,000 mechanical operations and 4,000 electrical operations.
Technical Specifications
| Hager NCN316A Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 16 A |
| Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 | 20 kA |
| Rated ultimate short-circuit breaking capacity Icu AC IEC 60947-2 | 15 kA |
| Rated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-2 | 15 kA |
| Rated current at -15°C | 19.56 A |
| Rated current at -10°C | 19.20 A |
| Rated current at -5°C | 18.83 A |
| Rated current at 0°C | 18.45 A |
| Rated current at 5°C | 18.07 A |
| Rated current at 10°C | 17.67 A |
| Rated current at 15°C | 17.27 A |
| Rated current at 20°C | 16.86 A |
| Rated current at 25°C | 16.43 A |
| Rated current at 30°C | 16 A |
| Rated current at 35°C | 15.48 A |
| Rated current at 40°C | 14.94 A |
| Rated current at 45°C | 14.38 A |
| Rated current at 50°C | 13.80 A |
| Rated current at 55°C | 13.19 A |
| Rated current at 60°C | 12.56 A |
| Rated current at 65°C | 11.89 A |
| Rated current at 70°C | 11.18 A |
| Rated short-circuit breaking capacity Icn under 400 V AC according to IEC 60898-1 | 10 kA |
| Rated service breaking capacity Ics AC according to IEC 60898-1 | 7.50 kA |
| Rated ultimate short-circuit breaking capacity Icu under 230 V AC IEC 60947-2 | 30 kA |
| Architecture and Capacity | |
| Type of pole | 3P |
| Curve | C |
| Number of modules | 3 |
| Installation and Mounting | |
| Nominal tightening torque top terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque down terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque | 2.80 - 2.80 Nm |
| Type of bottom connection for modular devices | biconnect |
| Type of top connection for modular devices | Screw terminal |
| 360° mounting position possible | Yes |
| Mechanical endurance | 20,000 operations |
| Electrical endurance | 4,000 operations |
| Voltage and Frequency | |
| Rated operational voltage Ue | 400 - 400 V |
| Type voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6,000 V |
| Frequency | 50 - 60 Hz |
| Connection | |
| Cross-section of input and output with screws, for massive conductors | 1 - 35 mm² |
| Cross-section of input and output with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for massive conductors | 1 - 35 mm² |
| Safety and Use Conditions | |
| Ingress Protection (IP) class | IP20 |
| Grid distance | 60 mm |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 2 |
| Class of energy limitation I²t | 3 |
| Operating temperature | -25 - 70 °C |
| Power and Connectivity | |
| Power dissipation at IN | 8.27 W |
| Type of connection | Screw terminal |
| Top connection alignment for modular devices | Aligned terminal |
| Down connection alignment for modular devices | Aligned terminal |
| Dimensions | |
| Height | 83 mm |
| Width | 52.50 mm |
| Depth | 70 mm |
| General | |
| EAN | 3250614615825 |
| RoHS conform | Yes |
What's in the Box
Hager NCN316A 3-pole 16 A Type C miniature circuit breaker. Accessories are not specified in the available product information.
Downloads
| Document | Format | Link |
|---|---|---|
| PEP - MCB 1P 6kA B-16A, 1 module (English) | Download PDF | |
| REACH declaration NCN316A | Download PDF | |
| RoHS report NCN316A | Download PDF |
For help checking compatibility or selecting the right protective device, please contact thelightinggallery.
Hager Miniature Circuit Breaker 3P 10A Curve C 15kA 400V Icn 10kA 3 Modules NCN310A
Hager Miniature Circuit Breaker 3P 10A Curve C 15kA 400V Icn 10kA 3 Modules NCN310A
Hager NCN310A 3-Pole 10A Type C MCB
The Hager NCN310A is a 3-pole miniature circuit breaker with a 10 A rated current and Type C curve. Designed for three-phase circuit protection, it protects against overload and short circuits in residential, commercial and light industrial panels. The breaker is rated at 400 V AC and includes screw and biconnect terminals for practical modular installation.
Key Features
- 3-pole protection: 3P configuration across three modules.
- Type C curve: Suitable for three-phase distribution and motor/control circuits.
- Breaking capacity: 10 kA Icn at 400 V AC according to IEC 60898-1, with 15 kA Icu at 400 V AC and 30 kA Icu at 230 V AC according to IEC 60947-2.
- Electrical rating: 10 A rated current, 400 V AC operating voltage and 50–60 Hz frequency.
- Connection: Screw and biconnect terminals accepting conductors from 1–35 mm², with aligned top and bottom connections.
- Compact modular format: Three modules wide, with IP20 protection and 360° mounting possible.
- Endurance: 20,000 mechanical operations and 4,000 electrical operations.
Technical Specifications
| Hager NCN310A Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 10 A |
| Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 | 20 kA |
| Rated ultimate short-circuit breaking capacity Icu AC IEC 60947-2 | 15 kA |
| Rated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-2 | 15 kA |
| Rated current at -15°C | 12.28 A |
| Rated current at -10°C | 12.05 A |
| Rated current at -5°C | 11.81 A |
| Rated current at 0°C | 11.57 A |
| Rated current at 5°C | 11.32 A |
| Rated current at 10°C | 11.07 A |
| Rated current at 15°C | 10.81 A |
| Rated current at 20°C | 10.55 A |
| Rated current at 25°C | 10.28 A |
| Rated current at 30°C | 10 A |
| Rated current at 35°C | 9.61 A |
| Rated current at 40°C | 9.21 A |
| Rated current at 45°C | 8.78 A |
| Rated current at 50°C | 8.33 A |
| Rated current at 55°C | 7.86 A |
| Rated current at 60°C | 7.36 A |
| Rated current at 65°C | 6.82 A |
| Rated current at 70°C | 6.24 A |
| Rated short-circuit breaking capacity Icn under 400 V AC according to IEC 60898-1 | 10 kA |
| Rated service breaking capacity Ics AC according to IEC 60898-1 | 7.50 kA |
| Rated ultimate short-circuit breaking capacity Icu under 230 V AC IEC 60947-2 | 30 kA |
| Architecture and Capacity | |
| Type of pole | 3P |
| Curve | C |
| Number of modules | 3 |
| Installation and Mounting | |
| Nominal tightening torque top terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque down terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque | 2.80 - 2.80 Nm |
| Type of bottom connection for modular devices | biconnect |
| Type of top connection for modular devices | Screw terminal |
| 360° mounting position possible | Yes |
| Mechanical endurance | 20,000 operations |
| Electrical endurance | 4,000 operations |
| Voltage and Frequency | |
| Rated operational voltage Ue | 400 - 400 V |
| Type voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6,000 V |
| Frequency | 50 - 60 Hz |
| Connection | |
| Cross-section of input and output with screws, for massive conductors | 1 - 35 mm² |
| Cross-section of input and output with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for massive conductors | 1 - 35 mm² |
| Safety and Use Conditions | |
| Ingress Protection (IP) class | IP20 |
| Grid distance | 60 mm |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 2 |
| Class of energy limitation I²t | 3 |
| Operating temperature | -25 - 70 °C |
| Power and Connectivity | |
| Power dissipation at IN | 6.13 W |
| Type of connection | Screw terminal |
| Top connection alignment for modular devices | Aligned terminal |
| Down connection alignment for modular devices | Aligned terminal |
| Dimensions | |
| Height | 83 mm |
| Width | 52.50 mm |
| Depth | 70 mm |
| General | |
| RoHS conform | Yes |
What's in the Box
Hager NCN310A 3-pole 10 A Type C miniature circuit breaker. Accessories are not specified in the available product information.
Downloads
| Document | Format | Link |
|---|---|---|
| PEP - MCB 1P 6kA B-16A, 1 module (English) | Download PDF | |
| REACH declaration NCN310A | Download PDF | |
| RoHS report NCN310A | Download PDF |
For help checking compatibility or selecting the right protective device, please contact thelightinggallery.
Hager MCB 3P 6A Curve C 15kA Icu 400V (10kA Icn) 3 Modules NCN306A
Hager MCB 3P 6A Curve C 15kA Icu 400V (10kA Icn) 3 Modules NCN306A
Hager NCN306A 3-Pole 6A Type C MCB
The Hager NCN306A is a 3-pole miniature circuit breaker with a 6 A rated current and Type C curve. Designed for three-phase circuit protection, it provides overload and short-circuit protection at 400 V AC, with screw and biconnect terminals for practical modular installation.
Key Features
- 3-pole protection: 3P configuration across three modules.
- Type C curve: Suitable for protecting three-phase distribution and motor/control circuits.
- Breaking capacity: 10 kA Icn at 400 V AC according to IEC 60898-1, with 15 kA Icu at 400 V AC according to IEC 60947-2.
- Electrical rating: 6 A rated current, 400 V AC operating voltage and 50–60 Hz frequency.
- Connection: Screw terminals with aligned top and bottom connections, plus biconnect compatibility at the bottom.
- Compact modular format: Three modules wide, with IP20 protection.
Technical Specifications
| Hager NCN306A Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 6 A |
| Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 | 20 kA |
| Rated ultimate short-circuit breaking capacity Icu AC IEC 60947-2 | 15 kA |
| Rated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-2 | 15 kA |
| Rated current at -15°C | 7.35 A |
| Rated current at -10°C | 7.21 A |
| Rated current at -5°C | 7.07 A |
| Rated current at 0°C | 6.93 A |
| Rated current at 5°C | 6.78 A |
| Rated current at 10°C | 6.63 A |
| Rated current at 15°C | 6.48 A |
| Rated current at 20°C | 6.32 A |
| Rated current at 25°C | 6.16 A |
| Rated current at 30°C | 6 A |
| Rated current at 35°C | 5.81 A |
| Rated current at 40°C | 5.61 A |
| Rated current at 45°C | 5.41 A |
| Rated current at 50°C | 5.19 A |
| Rated current at 55°C | 4.97 A |
| Rated current at 60°C | 4.74 A |
| Rated current at 65°C | 4.50 A |
| Rated current at 70°C | 4.24 A |
| Rated short-circuit breaking capacity Icn under 400 V AC according to IEC 60898-1 | 10 kA |
| Rated service breaking capacity Ics AC according to IEC 60898-1 | 7.50 kA |
| Rated ultimate short-circuit breaking capacity Icu under 230 V AC IEC 60947-2 | 30 kA |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 10 kA |
| Architecture and Capacity | |
| Type of pole | 3P |
| Curve | C |
| Number of modules | 3 |
| Installation and Mounting | |
| Nominal tightening torque top terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque down terminal | 2.80 - 2.80 Nm |
| Nominal tightening torque | 2.80 - 2.80 Nm |
| Type of bottom connection for modular devices | biconnect |
| Type of top connection for modular devices | Screw terminal |
| 360° mounting position possible | Yes |
| Voltage and Frequency | |
| Rated operational voltage Ue | 400 - 400 V |
| Type voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6,000 V |
| Frequency | 50 - 60 Hz |
| Connection | |
| Cross-section of input and output with screws, for massive conductors | 1 - 35 mm² |
| Cross-section of input and output with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for flexible conductors | 1 - 25 mm² |
| Cross-section of input with screws, for massive conductors | 1 - 35 mm² |
| Safety and Use Conditions | |
| Ingress Protection (IP) class | IP20 |
| Grid distance | 60 mm |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 2 |
| Class of energy limitation I²t | 3 |
| Operating temperature | -25 - 70 °C |
| Power and Connectivity | |
| Power dissipation at IN | 4.06 W |
| Type of connection | Screw terminal |
| Top connection alignment for modular devices | Aligned terminal |
| Down connection alignment for modular devices | Aligned terminal |
| Dimensions | |
| Height | 83 mm |
| Width | 52.50 mm |
| Depth | 70 mm |
| General | |
| EAN | 3250614615795 |
| RoHS conform | Yes |
What's in the Box
Hager NCN306A 3-pole 6 A Type C miniature circuit breaker. Accessories are not specified in the available product information.
Downloads
| Document | Format | Link |
|---|---|---|
| PEP - MCB 1P 6kA B-16A, 1 module (English) | Download PDF | |
| REACH declaration NCN306A | Download PDF | |
| RoHS report NCN306A | Download PDF |
For help checking compatibility or selecting the right protective device, please contact thelightinggallery.
Hager Miniature circuit breaker 1P 20A Curve C 10kA Icn 15kA Icu 1 Module NCN120A
Hager Miniature circuit breaker 1P 20A Curve C 10kA Icn 15kA Icu 1 Module NCN120A
Hager NCN120A 20A Type C Single-Pole Circuit Breaker
The Hager NCN120A is a high-performance 20A Type C miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. Its compact one-module format, 10kA rated short-circuit breaking capacity and Type C response make it suitable for compatible circuits with mixed or moderately inductive loads in residential and commercial distribution boards.
Key Features
- Rated current: 20A at 30°C
- Tripping curve: Type C
- Breaking capacities: 10kA Icn, 7.5kA Ics and 15kA Icu
- Configuration: Single pole (1P), one module
- Operating voltage: 230–400V AC
- Connection: Screw terminal with biconnect bottom connection
- Mounting flexibility: 360° mounting position possible
- Protection rating: IP20
Technical Specifications
| Hager NCN120A Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 20 A |
| Rated service breaking capacity Ics AC | 7.50 kA according to IEC 60898-1 |
| Rated short-circuit breaking capacity Icn at 230V AC | 10 kA according to IEC 60898-1 |
| Rated short-circuit breaking capacity Icn AC | 10 kA according to IEC 60898-1 |
| Rated ultimate short-circuit breaking capacity Icu AC | 15 kA according to IEC 60947-2 |
| Rated ultimate short-circuit breaking capacity Icu at 230V AC | 15 kA according to IEC 60947-2 |
| Rated operational voltage Ue | 230–400 V |
| Voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6,000 V |
| Frequency | 50–60 Hz |
| Power dissipation at IN | 2.56 W |
| Energy limitation class I²t | 3 |
| Architecture & Installation | |
| Number of poles | 1P |
| Tripping curve | C |
| Number of modules | 1 |
| Top connection | Screw terminal |
| Bottom connection | Biconnect |
| Connection alignment | Aligned terminal, top and bottom |
| Nominal tightening torque | 2.80–2.80 Nm |
| Mounting position | 360° mounting possible |
| Rigid conductor cross-section | 1–35 mm² |
| Flexible conductor cross-section | 1–25 mm² |
| Rated Current by Ambient Temperature | |
| -15°C | 24.24 A |
| -10°C | 23.80 A |
| -5°C | 23.36 A |
| 0°C | 22.91 A |
| 5°C | 22.45 A |
| 10°C | 21.98 A |
| 15°C | 21.51 A |
| 20°C | 21.02 A |
| 25°C | 20.51 A |
| 30°C | 20 A |
| 35°C | 19.47 A |
| 40°C | 18.93 A |
| 45°C | 18.37 A |
| 50°C | 17.80 A |
| 55°C | 17.20 A |
| 60°C | 16.58 A |
| 65°C | 15.94 A |
| 70°C | 15.28 A |
| Dimensions & General | |
| Height | 83 mm |
| Width | 17.50 mm |
| Depth | 70 mm |
| Ingress protection | IP20 |
| Grid distance | 60 mm |
| Pollution degree | 2 according to IEC 60664 / IEC 60947-2 |
| Operating temperature | -25–70°C |
| EAN | 3250614615535 |
What's in the Box
- 1 × Hager NCN120A 20A Type C single-pole circuit breaker
Need help checking compatibility with your distribution board or installation? Contact The Lighting Gallery team before ordering. Electrical installation should be carried out by a suitably qualified professional.
Hager Miniature circuit breaker 1P 6A Curve C 10kA Icn 15kA Icu 1 Module NCN106A
Hager Miniature circuit breaker 1P 6A Curve C 10kA Icn 15kA Icu 1 Module NCN106A
Hager NCN106A 6A Type C Single-Pole Circuit Breaker
The Hager NCN106A is a high-performance 6A Type C miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. Its compact one-module format, 10kA rated short-circuit breaking capacity and Type C response make it suitable for compatible circuits with mixed or moderately inductive loads in residential and light-commercial distribution boards.
Key Features
- Rated current: 6A at 30°C
- Tripping curve: Type C
- Breaking capacities: 10kA Icn, 7.5kA Ics and 15kA Icu
- Configuration: Single pole (1P), one module
- Operating voltage: 230–400V AC
- Connection: Screw terminal with biconnect bottom connection
- Endurance: 20,000 mechanical and 4,000 electrical operations
- Mounting flexibility: 360° mounting position possible
- Protection rating: IP20
Technical Specifications
| Hager NCN106A Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 6 A |
| Rated service breaking capacity Ics AC | 7.50 kA according to IEC 60898-1 |
| Rated short-circuit breaking capacity Icn at 230V AC | 10 kA according to IEC 60898-1 |
| Rated short-circuit breaking capacity Icn AC | 10 kA according to IEC 60898-1 |
| Rated ultimate short-circuit breaking capacity Icu AC | 15 kA according to IEC 60947-2 |
| Rated ultimate short-circuit breaking capacity Icu at 230V AC | 15 kA according to IEC 60947-2 |
| Rated operational voltage Ue | 230–400 V |
| Voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6,000 V |
| Frequency | 50–60 Hz |
| Power dissipation at IN | 1.33 W |
| Energy limitation class I²t | 3 |
| Architecture & Installation | |
| Number of poles | 1P |
| Tripping curve | C |
| Number of modules | 1 |
| Top connection | Screw terminal |
| Bottom connection | Biconnect |
| Connection alignment | Aligned terminal, top and bottom |
| Nominal tightening torque | 2.80–2.80 Nm |
| Mounting position | 360° mounting possible |
| Rigid conductor cross-section | 1–35 mm² |
| Flexible conductor cross-section | 1–25 mm² |
| Mechanical endurance | 20,000 operations |
| Electrical endurance | 4,000 operations |
| Rated Current by Ambient Temperature | |
| -15°C | 7.26 A |
| -10°C | 7.13 A |
| -5°C | 7 A |
| 0°C | 6.87 A |
| 5°C | 6.73 A |
| 10°C | 6.59 A |
| 15°C | 6.45 A |
| 20°C | 6.30 A |
| 25°C | 6.15 A |
| 30°C | 6 A |
| 35°C | 5.84 A |
| 40°C | 5.68 A |
| 45°C | 5.52 A |
| 50°C | 5.35 A |
| 55°C | 5.17 A |
| 60°C | 4.99 A |
| 65°C | 4.80 A |
| 70°C | 4.60 A |
| Dimensions & General | |
| Height | 83 mm |
| Width | 17.50 mm |
| Depth | 70 mm |
| Ingress protection | IP20 |
| Grid distance | 60 mm |
| Pollution degree | 2 according to IEC 60664 / IEC 60947-2 |
| Operating temperature | -25–70°C |
| EAN | 3250614615498 |
What's in the Box
- 1 × Hager NCN106A 6A Type C single-pole circuit breaker
Need help checking compatibility with your distribution board or installation? Contact The Lighting Gallery team before ordering. Electrical installation should be carried out by a suitably qualified professional.
Hager NBN120A 20A Type B Single-Pole Circuit Breaker
The Hager NBN120A is a high-performance 20A Type B miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. Its compact one-module format combines a 10kA rated short-circuit breaking capacity with biconnect terminals for compatible residential and commercial distribution boards.
Key Features
- Rated current: 20A at 30°C
- Tripping curve: Type B
- Breaking capacities: 10kA Icn, 7.5kA Ics and 15kA Icu
- Configuration: Single pole (1P), one module
- Operating voltage: 230–400V AC
- Connection: Screw terminal with biconnect bottom connection
- Mounting flexibility: 360° mounting position possible
- Protection rating: IP20
Technical Specifications
| Hager NBN120A Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 20 A |
| Rated service breaking capacity Ics at 230V AC | 7.50 kA according to IEC 60947-2 |
| Rated service breaking capacity Ics AC | 50% according to IEC 60947-2 |
| Rated service breaking capacity Ics AC | 7.50 kA according to IEC 60898-1 |
| Rated short-circuit breaking capacity Icn at 230V AC | 10 kA according to IEC 60898-1 |
| Rated short-circuit breaking capacity Icn AC | 10 kA according to IEC 60898-1 |
| Rated ultimate short-circuit breaking capacity Icu AC | 15 kA according to IEC 60947-2 |
| Rated ultimate short-circuit breaking capacity Icu at 230V AC | 15 kA according to IEC 60947-2 |
| Rated operational voltage Ue | 230–400 V |
| Voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6,000 V |
| Frequency | 50–60 Hz |
| Power dissipation at IN | 2.56 W |
| Energy limitation class I²t | 3 |
| Architecture & Installation | |
| Number of poles | 1P |
| Tripping curve | B |
| Number of modules | 1 |
| Top connection | Screw terminal |
| Bottom connection | Biconnect |
| Connection alignment | Aligned terminal, top and bottom |
| Nominal tightening torque | 2.80–2.80 Nm |
| Mounting position | 360° mounting possible |
| Rigid conductor cross-section | 1–35 mm² |
| Flexible conductor cross-section | 1–25 mm² |
| Rated Current by Ambient Temperature | |
| -15°C | 24.24 A |
| -10°C | 23.80 A |
| -5°C | 23.36 A |
| 0°C | 22.91 A |
| 5°C | 22.45 A |
| 10°C | 21.98 A |
| 15°C | 21.51 A |
| 20°C | 21.02 A |
| 25°C | 20.51 A |
| 30°C | 20 A |
| 35°C | 19.47 A |
| 40°C | 18.93 A |
| 45°C | 18.37 A |
| 50°C | 17.80 A |
| 55°C | 17.20 A |
| 60°C | 16.58 A |
| 65°C | 15.94 A |
| 70°C | 15.28 A |
| Dimensions & General | |
| Height | 83 mm |
| Width | 17.50 mm |
| Depth | 70 mm |
| Ingress protection | IP20 |
| Grid distance | 60 mm |
| Pollution degree | 2 according to IEC 60664 / IEC 60947-2 |
| Operating temperature | -25–70°C |
| EAN | 3250614618055 |
What's in the Box
- 1 × Hager NBN120A 20A Type B single-pole circuit breaker
Need help checking compatibility with your distribution board or installation? Contact The Lighting Gallery team before ordering. Electrical installation should be carried out by a suitably qualified professional.
Hager Circuit breaker 1P 6A Curve B 10kA Icn / 15kA Icu 1 Module NBN106A
Hager Circuit breaker 1P 6A Curve B 10kA Icn / 15kA Icu 1 Module NBN106A
Hager NBN106A 6A Type B Single-Pole Circuit Breaker
The Hager NBN106A is a high-performance 6A Type B miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. Its compact one-module design combines a 10kA rated short-circuit breaking capacity with biconnect terminals for use in compatible residential and light-commercial distribution boards.
Key Features
- Rated current: 6A at 30°C
- Tripping curve: Type B
- Breaking capacities: 10kA Icn, 7.5kA Ics and 15kA Icu
- Configuration: Single pole (1P), one module
- Operating voltage: 230–400V AC
- Connection: Screw terminal with biconnect bottom connection
- Endurance: 20,000 mechanical and 4,000 electrical operations
- Mounting flexibility: 360° mounting position possible
- Protection rating: IP20
- Environmental compliance: RoHS conform
Technical Specifications
| Hager NBN106A Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 6 A |
| Rated service breaking capacity Ics at 230V AC | 7.50 kA according to IEC 60947-2 |
| Rated service breaking capacity Ics AC | 50% according to IEC 60947-2 |
| Rated service breaking capacity Ics AC | 7.50 kA according to IEC 60898-1 |
| Rated short-circuit breaking capacity Icn at 230V AC | 10 kA according to IEC 60898-1 |
| Rated short-circuit breaking capacity Icn AC | 10 kA according to IEC 60898-1 |
| Rated ultimate short-circuit breaking capacity Icu AC | 15 kA according to IEC 60947-2 |
| Rated ultimate short-circuit breaking capacity Icu at 230V AC | 15 kA according to IEC 60947-2 |
| Rated operational voltage Ue | 230–400 V |
| Voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6,000 V |
| Frequency | 50–60 Hz |
| Power dissipation at IN | 1.33 W |
| Energy limitation class I²t | 3 |
| Architecture & Installation | |
| Number of poles | 1P |
| Tripping curve | B |
| Number of modules | 1 |
| Top connection | Screw terminal |
| Bottom connection | Biconnect |
| Connection alignment | Aligned terminal, top and bottom |
| Nominal tightening torque | 2.80–2.80 Nm |
| Mounting position | 360° mounting possible |
| Rigid conductor cross-section | 1–35 mm² |
| Flexible conductor cross-section | 1–25 mm² |
| Mechanical endurance | 20,000 operations |
| Electrical endurance | 4,000 operations |
| Rated Current by Ambient Temperature | |
| -15°C | 7.26 A |
| -10°C | 7.13 A |
| -5°C | 7 A |
| 0°C | 6.87 A |
| 5°C | 6.73 A |
| 10°C | 6.59 A |
| 15°C | 6.45 A |
| 20°C | 6.30 A |
| 25°C | 6.15 A |
| 30°C | 6 A |
| 35°C | 5.84 A |
| 40°C | 5.68 A |
| 45°C | 5.52 A |
| 50°C | 5.35 A |
| 55°C | 5.17 A |
| 60°C | 4.99 A |
| 65°C | 4.80 A |
| 70°C | 4.60 A |
| Dimensions & General | |
| Height | 83 mm |
| Width | 17.50 mm |
| Depth | 70 mm |
| Ingress protection | IP20 |
| Grid distance | 60 mm |
| Pollution degree | 2 according to IEC 60664 / IEC 60947-2 |
| Operating temperature | -25–70°C |
| RoHS conform | Yes |
| EAN | 3250614618017 |
What's in the Box
- 1 × Hager NBN106A 6A Type B single-pole circuit breaker
Downloads
| Document | Download |
|---|---|
| Product Environmental Profile – MCB 1P 6kA B-16A, 1 module | View PDF |
| REACH Declaration – NBN106A | View PDF |
| RoHS Report – NBN106A | View PDF |
Need help checking compatibility with your distribution board or installation? Contact The Lighting Gallery team before ordering. Electrical installation should be carried out by a suitably qualified professional.
Hager MTN150 50A Type B Single-Pole MCB
The Hager MTN150 is a compact 50A Type B miniature circuit breaker designed to protect electrical circuits against overloads and short circuits. Its single-pole, one-module format, 6kA breaking capacity and biconnect terminal system provide dependable circuit protection in compatible residential and light-commercial distribution boards.
Key Features
- Rated current: 50A at 30°C
- Tripping curve: Type B
- Breaking capacity: 6kA
- Configuration: Single pole (1P), one module
- Operating voltage: 230–400V AC
- Connection: Screw terminal with biconnect bottom connection
- Mounting flexibility: 360° mounting position possible
- Protection rating: IP20
- Environmental compliance: RoHS conform
Technical Specifications
| Hager MTN150 Technical Data | |
|---|---|
| Electrical | |
| Rated current IN | 50 A |
| Rated service breaking capacity Ics at 230V AC | 6 kA according to IEC 60947-2 |
| Rated short-circuit breaking capacity Icn at 230V AC | 6 kA according to IEC 60898-1 |
| Rated short-circuit breaking capacity Icn AC | 6 kA according to IEC 60898-1 |
| Rated operational voltage Ue | 230–400 V |
| Voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 4,000 V |
| Frequency | 50–60 Hz |
| Power dissipation at IN | 4.7 W |
| Energy limitation class I²t | 3 |
| Architecture & Installation | |
| Number of poles | 1P |
| Tripping curve | B |
| Number of modules | 1 |
| Top connection | Screw terminal |
| Bottom connection | Biconnect |
| Connection alignment | Aligned terminal, top and bottom |
| Nominal tightening torque | 2.80–2.80 Nm |
| Mounting position | 360° mounting possible |
| Rigid conductor cross-section | 1–35 mm² |
| Flexible conductor cross-section | 1–25 mm² |
| Rated Current by Ambient Temperature | |
| -15°C | 62.8 A |
| -10°C | 61.4 A |
| -5°C | 60 A |
| 0°C | 58.5 A |
| 5°C | 57.1 A |
| 10°C | 55.7 A |
| 15°C | 54.3 A |
| 20°C | 52.8 A |
| 25°C | 51.4 A |
| 30°C | 50 A |
| 35°C | 49.2 A |
| 40°C | 48.5 A |
| 45°C | 47.7 A |
| 50°C | 47 A |
| 55°C | 46.2 A |
| 60°C | 45.4 A |
| 65°C | 44.7 A |
| 70°C | 43.9 A |
| Dimensions & General | |
| Height | 83 mm |
| Width | 17.5 mm |
| Depth | 70 mm |
| Ingress protection | IP20 |
| Grid distance | 60 mm |
| Pollution degree | 2 according to IEC 60664 / IEC 60947-2 |
| Air humidity protection | For all climates |
| Operating temperature | -25–70°C |
| RoHS conform | Yes |
| EAN | 3250614343094 |
What's in the Box
- 1 × Hager MTN150 50A Type B single-pole MCB
Downloads
| Document | Download |
|---|---|
| Product Environmental Profile – MCB 1P 6kA B-16A, 1 module | View PDF |
| REACH Declaration – MTN150 | View PDF |
| RoHS Report – MTN150 | View PDF |
Need help checking compatibility with your distribution board or installation? Contact The Lighting Gallery team before ordering. Electrical installation should be carried out by a suitably qualified professional.